r/AskElectricians • • Jul 21 '23

This subreddit and where we currently are.

305 Upvotes

After much discussion about how the community should be moderated, this is where we currently are.

First I want to get this out of the way. We will not allow hate speech, personal attacks, slurs, bigotry, or anything that resembles it. Okay? Good.

People are going to post electrical questions on the internet, do their own electrical work, and fuck up their own electrical work. This process will happen with or with out this subreddit and its rules. If there is a reliable community where someone can come and get good information on a wide range of electrical topics, then to me there will be a net positive for safety.

We are going to be allowing comments from all users, BUT I urge those who are not electrical professionals to exercise extreme caution when doing so. If information is not blatantly hazardous, it will stay up. The community is going to be asked to use the voting system it is intended. If someone takes the advice of a comment with negative karma, then more than likely, they would have done the wrong thing regardless. Once corrected, leaving wrong comments up can be a learning experience for everyone involved.

I ask you to DOWNVOTE information you do not like, and REPORT the hazardous stuff. We will decide what to do from there. Bans may or may not be given and everything will be at the discretion of the mods. Again, if you are someone who is not an electrical professional, you have been warned.

Electrical professionals: We have an imperfect system for getting a little 'Verified Electrician' flair next to your name. To get verified, send a photo to the mods that has your certificate/seal/card. In this photo, have a piece of paper with your username and date written on it. Block out all identifying information. Once verified delete the image. All the cool ones have this flair.

If we have hundreds or thousands of active verified users, we will once again talk about the direction of this community. Till then, see you in the comments.

​


r/AskElectricians • • 5h ago

Did this rice cooker cord get cut or was this wear and tear?

Thumbnail gallery
140 Upvotes

This is totally based on assumptions but I’ve had issues with my college roommate, and he would complain about the rice cooker smelling when it’s getting cooked. I always check if the cooker is on, but when I came back today, it was off. I checked the cord, this is what it looked like. I just have a slight feeling it might have been him.

But maybe it’s that I’ve never checked the cord and it eventually got like this. I’ve used it for around 1 year now.

Also, how do I even prove it was/wasn’t him ? Is this something you have to just deal with?


r/AskElectricians • • 13h ago

Light Switch Screws

Post image
201 Upvotes

A few years ago I read a post on here asking everyone if they vertically aligned the screws when installing a light switch plate. About 90% of the responses were emphatically yes the rest were "eh, I don't care." Except one dude. He responded with "I'd make sure I tighten them to the specific torque recommended for the screw." He was dragged in the responses.

To that one dude: I chuckle and think of that comment every single time I put on a light switch plate. And if you're reading this, I hope you're having a good day, man.


r/AskElectricians • • 3h ago

Single gang box clamp push out, inspector say no

Post image
22 Upvotes

An inspector claim 40 years experience, but say it needs to keep the clamps to hold on the romex wire. But the truth is most single gang box’s clamps can not hold anything, when pushing 12/2 cable wire it will be pushed off. The NEC code has such exception for single gang box.
Inspector pointed 4 problems, 2 of them are not corrected, spent a lot of time to check with state and get back the inspector.


r/AskElectricians • • 11h ago

Electrocution

33 Upvotes

Hello, plumber here (don’t be mean, I love you)
I had a question of why this time was different, I’ve been shocked many times by 120 but this one was weird.
As I understand it’s almost impossible to be hit by true 240 so let me lay out what happened.
I was too trusting and had a mislabeled water heater breaker off.
Took the nut off the black wire and went to untwist the wire, and surprise it was live.
I had my left hand on the heater and my right on the wire and I got stuck for a second or so but it went up my arm and straight to my right eye and I saw an electric like flash through my right eye for like 10 seconds.
It didn’t hurt too bad but was a lot of pressure and for 30 minutes or so it felt like someone poured bleach in my eye.
Pressure is still there a few hours later but going away.

Why was this one more extreme than any other time?


r/AskElectricians • • 4h ago

Outlet that had space heater plugged in looks like this

Post image
4 Upvotes

It’s been in use for about three winters now and I only noticed it when moving things recently. My intuition is to not plug the space heater back in, but what else should I take away from this and be concerned about? Should I not plug the space heater in anywhere else? Should I stop using this plug entirely? Is there anything I or a professional should inspect?

Other context - space heater was plugged directly into the wall per the product’s instructions. I always use the timer setting and it runs max 9 hours a day. Plug below it is a power strip but currently only has a TV plugged in that isn’t used often.


r/AskElectricians • • 13h ago

Anyone get zapped by the 480v? How'd it happen, did you learn anything, how'd it turn out?

23 Upvotes

Asking for a friend.


r/AskElectricians • • 8h ago

Splicing old K&T / Bx cloth wrapped w/ Romex

Thumbnail gallery
7 Upvotes

Have 1 live old Bx box with Hot and Neutral. Would like to Splice into a new J box > Switchboard > Wall Sconce + Ceiling Fixture.

Any advice on what to do? What to avoid? When you splice the old wires into the Romex, where will the final ground terminate at ?


r/AskElectricians • • 1h ago

Struggling to get started

• Upvotes

I’m 20 and live about an hour south of Tacoma, WA. I’m trying to get into the electrical trade, but I have limited experience. I enjoy working with my hands, learn quickly, and don’t mind hard work.
I’ve reached out to over 30 electrical companies and contractors in my area about entry level helper positions, apprenticeships, or trainee opportunities, but almost all of them have said they aren’t taking on beginners.
I’m serious about making this a career, but I’m struggling to figure out how to get my foot in the door.
Should I focus on applying directly to apprenticeship programs? Are there any programs or contractors around Pierce or Thurston County you’d recommend?
I’d appreciate any advice. Thanks!


r/AskElectricians • • 1h ago

How to access locked junction box for MoCA connection?

Thumbnail gallery
• Upvotes

Powerline adapter and wifi extender dont work in my basement rental room very well. Router on coaxial cable had moca option so I got a moca adapter but the coax port doesnt work. The box is shut, the ISP (Rogers, Toronto) said they wont help and I doubt my slumlord and my broke self would be able to afford an electrician. Any way to access it so I can either install a new splitter or attach the wires if disconnected? The black wire goes down to my basement room and there are like 6 coaxial cables but none of them are responsive to my adapter.


r/AskElectricians • • 8h ago

Orange mark on outlet

Thumbnail gallery
6 Upvotes

I went to unplug my microwave today and there’s this orange mark on the outlet and the plug looks like this. Is the microwave plug/outlet still safe to use?


r/AskElectricians • • 8h ago

How to disconnect wires from push terminal

Post image
8 Upvotes

I am at my wits end. How do i disconnect the wires going to the right in this picture? Ive tried to push a small screwdriver in through the holes next to the texts( 1, 2, ground, N, 3) and nothing. Nothing feels like moving and the wires wont loosen. I also tried to stick a pin in the holes right above the wires coming out(on the right) and nothing.


r/AskElectricians • • 16m ago

Before I call an electrician

• Upvotes

Background

I've just moved into a new-to-me house, built in 1958 with obvious remodels over the years. We had a typical real-estate purchase inspection, which as everybody knows is largely superficial. There was electrical work done some time back under a permit, and the permit had expired without final inspection. As part of the purchase, we required that be addressed, which it was inspected and approved by the city.

BTW out inspector did find a number of things, which were either fixed or we got the price adjusted. He just didn't find this.

The Breaker Box

On the panel is a 220v double breaker 40A, labeled "Oven - 240v not in use". Note the actual range is gas, with 110v power. There is a 15A breaker labeled "Kitchen Lights Oven".

Note the oven is supposed to have a 20A dedicated line, but hold that thought.

In the Garage

Directly across the wall from the range, is a 220v outlet. Presumably for an EV but not stated. My assumption was they took the "Unused" Oven 240 and ran it into the garage.

Issue #1 220v outlet wiring

Should measure 220v between the two hot lines. Should measure 110v from each hot to Ground, and should measure 110v from each hot to Neutral, and should measure 0v from ground to Neutral.

Actually measures 0v between the two hot lines. Measures 240v from each hot to Ground, and measures 110v from each hot to Neutral. (I think the two hots are actually wired to a single hot line, and the Ground is wired to the second hot, and the Neutral leg is either Ground or Neutral, but what do I know I'm a frickin software engineer).

Issue #2 Oven

When I turn the 220v breaker off (because I think it's whack), the oven loses power. Soooo the 110v oven is powered by one leg of the 220v. Which I expect is completely wrong and perhaps unsafe? I'm not sure half the 220v breaker would pop if the oven had a fault.

Tell me if I'm wrong, please.

So it looks like someone who didn't know what they were doing tried to wire a 220v outlet for an EV while using half that to power a new smart oven across the wall, that needed 20A.

Insert your own profanity here.


r/AskElectricians • • 1h ago

Need help installing Lutron humidity sensor switches in two bathrooms. What am I doing wrong?

Thumbnail gallery
• Upvotes

I've been trying to install Lutron humidity sensor switches in two of my bathrooms, and I'm honestly getting pretty frustrated. Both bathroom fans have a black wire and a white (neutral) wire.

The instructions show two different wiring scenarios, so I tried both but neither worked.

Scenario 1:

  • Connected the fan's neutral wire, the Lutron's white/green wire (removed the green sleeve), and the bundle of neutral wires together.
  • Connected one black wire from the Lutron to the fan's black wire.
  • Connected the other black wire from the Lutron to the bundle of black wires.
  • Connected the Lutron's ground wire to the bare copper ground wire.

Results:

  • Bathroom 1: The Lutron switch lights up, but pressing the button doesn't turn on the fan.
  • Bathroom 2: The breaker trips when the Lutron's black wire is connected to the bundle of black wires.

Scenario 2:

  • Connected one of the Lutron's black wires to the fan's neutral wire.
  • Connected the other Lutron black wire to the fan's black wire.
  • Connected the Lutron's green/white wire to the bare copper ground wire.

Results:

  • Neither bathroom fan worked.

At this point I'm completely stumped. I thought I was following the instructions correctly, but clearly I'm missing something. I've stopped testing different connections for now because I don't want to damage anything or create a safety issue.

Has anyone installed one of these Lutron humidity sensor switches before and run into something similar? Could I be misunderstanding the wiring diagram, or is there something about my existing wiring that's causing the issue?

Any advice would be greatly appreciated. THANK YOU!


r/AskElectricians • • 1h ago

Who should I call code compliance or fire department or electric company

• Upvotes

We recently moved into a rental house and I noticed in the new water heater closet that there's what looks like a orange extension cord wire feeding power to the receptacle which the water heater big gray #8 cord is plugged into. I feel like this is a fire waiting to happen. I did install a smoke alarm in this closet because it doesn't look right. I say it's an extension cord wire because I have a extension cord that looks identical to it. The landlord said his maintenance guy just built that room and he trust him it's done right


r/AskElectricians • • 1h ago

IBEW Local 120

Thumbnail
• Upvotes

r/AskElectricians • • 2h ago

Controlling fan and light separately from two locations (Ontario)

1 Upvotes

I want to have a ceiling fan with light (sharing neutral) to be controlled from two locations.

Is this a code compliant way of wiring it:

My understanding is that marking the white conductors with red or black tape is not required in this case but it's not prohibited either.

P.S. Grounding conductors are omitted for clarity.


r/AskElectricians • • 2h ago

If I am using a metal connector in a plastic enclosure, do I need a bonding bushing?

1 Upvotes

r/AskElectricians • • 3h ago

How much do you guys think it will cost to replace this box to a 200amp box ?

Post image
0 Upvotes

r/AskElectricians • • 7h ago

Old panel - can replacement wait?

Thumbnail gallery
2 Upvotes

This is a house we inherited in southern California (San Diego).

The house was built in 1968, is about 3000 square feet and has AC, electric oven, range top, etc.

I'll eventually get an electrician to check things out, but does anything look like an imminent danger from this view of the panel? I don't like how the bottom part looks open and I can see cables inside, but anything else?

Thanks!


r/AskElectricians • • 4h ago

Scuffed power cord on new dehumidifier

Thumbnail gallery
0 Upvotes

New dehumidifier power cord. Does this look purely superficial to you guys, or should the cord/unit be replaced?


r/AskElectricians • • 4h ago

Help with chewed up AC unit cord

Post image
0 Upvotes

Could I fix this cord by connecting the right colored wires and what’s with all the wires exposed around the colored wires?


r/AskElectricians • • 8h ago

England, commercial property - does this need replacing?

Thumbnail gallery
2 Upvotes

Hi all,

How old/fucked is this? Electrician has said he wont sign off on work done to it without replacing the fuseboxes because its all old and non-compliant with modern regs here in the uk.


r/AskElectricians • • 4h ago

Subpanel feeding multiple mini split wiring size

1 Upvotes

I will be installing six individual mini splits in my house. Two will be on one side of the house, four on the other to keep the linesets as short as possible. The units are all Pioneer Ultra 9000/9500BTU.

Rated current heat/cool 3.3A

MCA 10A

MOCP 15A

Homeline 4/8 space subpanels will have individual 15A breakers in it to serve as the disconnects for the units with 14AWG in liquidtite whips running to each. My question is about sizing the feeder wire and breaker in the main panel for the bank of four. The units use cooling mode to defrost if they would ever need to (in the last decade it has only made it below freezing twice), so that rated current figure should be their maximum load. NEC has provisions carved out already for sizing feeders to multiple motors, but I'm not exactly sure how it applies to this scenario since each unit's full power is below the MCA, and I'm not sure if the MCA would be additive when sizing back to a main panel. The run is about 45 feet of wire. Just trying to figure out if a 20A 2p breaker and 12AWG is kosher or if I'd need to use a 40A breaker and 8AWG and just sell off one of the kids.

Thank you.


r/AskElectricians • • 5h ago

How is this light supposed to be wired?

Thumbnail gallery
1 Upvotes

My girlfriend and I bought a condo recently and one of the light fixtures was falling off the roof after a week or so, turns out that the previous owner just glued them to the roof 🤦 I took it off to correct the mistake and properly attached it, only after I finished I realized that the switch won't turn it off anymore. It just stays on. So I looked behind the switch and it turns out that there's two black wires, a red wire, and no white wires? How the hell is this thing supposed to be wired to the switch? Am I an idiot, or is it the person who installed this thing?

Please help me. What do I do? I thought I wired it how it was done before, but obviously something is wrong. The red wire was never connected to anything, it was just covered in electrical tape